Solar street light system is not standard system, is based on the requirements of each user for different configurations, such as: night lighting time, rainy days, the sun coefficient and so on. Irrational configuration of solar street lights make the entire system overloaded, resulting in overheating of the cable, wire nose overheating, reduce insulation, grounding short circuit and so on; the other hand, the design of the pole only consider the light pole itself, ignoring the cable head Of the space, after the first cable wrapped, most of the doors are closed, and sometimes the cable length is not enough, the connector does not meet the requirements, which is also a factor in failure.